71578 Masterline 8 Hi 3d Detail

Performance

Energy

Thermal Insulation(1) EN ISO 10077-2

Uf-value down to 1.6 W/m2K depending on the frame/vent combination and the glass thickness.

Performance

Comfort

Acoustic performance(3) ASTM E90- 09/1332

STC 43 42 39 40

Acoustic performance(3) ASTM E90- 09/1332

OITC 36 35 36 36

Air tightness, max. test pressure(4) (cfm/ft2)

0.04 0.04 0.02 0.27

Water tightness(5) (psf)

12.11 15 2.92 9.4

AAMA Rating AAMA/WDMA/CSA 101/I.S.2/A440, NAFS

AW PG120 CW PG 100 DAW AW PG 100 C R PG15 CW PG50

TAS 202/203-94 TAS 201

DP +/-65 psf Large Missile Impact

Safety

Burglar resistance

WK 1 WK 2 WK 3

* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. visible width inward opening window (Frame)

2 3/16”

Min. visible width inward opening window (Vent)

1 5/16”

Min. visible width outward opening window (Frame)

11/16”

Min. visible width outward opening window (Vent)

3”

Min. visible width inward opening flush door (Frame)

2 11/16”

Min. visible width inward opening flush door (Vent)

3”

Min. visible width outward opening flush door (Frame)

1 5/8”

Min. visible width outward opening flush door (Vent)

4”

Min. visible width T-profile

3”

Overall system depth window(Frame)

2 11/16”

Overall system depth window(Vent)

3 1/16”

Glazing

Rebate height

1”

Glass thickness

up to 2 1/16”

Glazing method

dry glazing with EPDM or neutral silicones

Max. glass thickness - frame/element

2 7/16 inch

Thermal insulation

1 1/4” omega and/or hollow chamber –shaped fibreglass reinforced polyamide strips

High Insulation variant (HI)

Available

High Insulation Plus variant (HI+)

Available